AIR CYLINDER: 2" dia. bore.
LENGTH OF STROKE: 18", 24", 30" and 36" available.
PUSHER PLATE: 30" wide x 6" high x 1/8" aluminum channel.
MAXIMUM CYCLE RATE: 35 cycles/min.
PUSH-OFF CYCLE TIME: 0.8 second second per cycle.
FRL: Included, w/ 3/8" ports.
COMPRESSED AIR: 0.5 cu. ft./min. at 80 to 100 PSI per cycle.
ENCLOSURE: NEMA 1 houses terminal strip for all wiring connections.
|
WIRING DIAGRAM: Housed inside of terminal box.
ELECTRICAL CONTROLS: 115 volt, single phase, 60 hertz 50 millisecond pulse signal. Unit also includes following controls: 3-position control switch--(1) auto, (2) off, (3) test; sensor to detect complete push-off cycle; stall timer; signal to stop conveyor if cycle time exceeds time set on stall timer.
MISC. TERMINALS: Provided for wiring to back-up sensors which inhibit diverter action until condition is cleared. Terminals also provided for connecting back-up warning light and buzzer and for connecting a push-off cycle counter. |